Fire Resistant and Low-Smoke Halogen Free Cables

Fire Resistant and Low-Smoke Halogen Free Cables
0.6/1KV-FRLH-IE

600/1000 V 90°C CROSS-LINKED POLYETHYLENE INSULATED FLAME RETARDANT WITH LOW SMOKE AND ZERO HALOGEN POWER CABLE

CONDUCTOR
    Non-Compacted and compacted round annealed copper 
>
>
>
INSULATION
    Flame retardant Low smoke and halogen free Cross-linked polyethylene (LSHF-XLPE:EI5)
>
CORE IDENTIFICATION
    Single-Cores: Black or Orange
>
>
>
>
>
>
>
>
>
>
CLASSIFICATION
    Maximum conductor temperature 90°C
    Circuit voltage not exceeding 1,200 Volts
RATED VOLTAGE
      600 Volts between Line to Earth
      1,000 Volts between Line to Line
TESTING VOLTAGE
    3,500 V
REFERENCE STANDARD
    Construction : BS EN 50525-3-41 
    Flame retardant : BS EN 60332-1-2 
                           BS EN IEC 60332-3-22 Category A 
                           BS EN IEC 60332-3-23 Category B
                           BS EN IEC 60332-3-24 Category C 
    Acid gas emission : BS EN 60754-1, BS EN 60754-2 
    Smoke emission : BS EN 61034-2 
    Non-toxic gases : Defence standard 02-713
APPLICATION
    For Fixed installation in electrical cabinet, conduit and wireway which provide flame retardant, low smoked and non toxic emission under fire
FDLH-0.6/1KV-CE

0.6/1kV 90°C CROSS-LINKED POLYETHYLENE INSULATED POLYOLEFIN SHEATHED FLAME RETARDANT WITH LOW SMOKE AND ZERO HALOGEN POWER CABLE

CONDUCTOR
    Non-Compacted and compacted round annealed copper 
>
>
>
INSULATION
    Cross-Linked polyethylene(XLPE)
>
CORE IDENTIFICATION
    Single-core : Natural (Translucent)
    2 Core : Blue and Brown
    3 Core : Brown, Black and Grey
    4 Core : Blue, Brown, Black and Grey
>
>
>
>
>
>
>
>
>
OUTER SHEATH
    Black Low smoke and zero halogen flame retardant polyolefin (ST8)
CLASSIFICATION
    Maximum conductor temperature 90°C
    Circuit voltage not exceeding 1,200 Volts
RATED VOLTAGE
    600 Volts between Line to Earth
    1,000 Volts between Line to Line
TESTING VOLTAGE
    3,500 V
REFERENCE STANDARD
    Construction : IEC 60502-1
    Flame retardant : BS EN 60332-1-2 
                           BS EN IEC 60332-3-22 Category A 
                           BS EN IEC 60332-3-23 Category B
                           BS EN IEC 60332-3-24 Category C 
    Acid gas emission : BS EN 60754-1, BS EN 60754-2 
    Smoke emission : BS EN 61034-2 
    Non-toxic gases : Defence standard 02-713
APPLICATION
    For Fixed installation in electrical cabinet, conduit and wireway which provide flame retardant, low smoked and non toxic emission under fire
FDLH-0.6/1KV-CE-SWA

0.6/1kV 90°C ALUMINIUM CONDUCTOR CROSS-LINKED POLYETHYLENE INSULATED PVC SHEATHED, WITH GALVANIZED STEEL WIRE ARMORED FLAME RETARDANT POWER CABLE

CONDUCTOR
    Non-Compacted and compacted round annealed copper 
>
>
>
INSULATION
    Cross-Linked polyethylene(XLPE)
>
CORE IDENTIFICATION
    2 Core : Blue and Brown
    3 Core : Brown, Black and Grey
    4 Core : Blue, Brown, Black and Grey
>
>
INNER SHEATH
    Black Low smoke and zero halogen flame retardant polyolefin (ST8)
>
>
>
ARMOUR
    Galvanized Steel Wires
>
>
OUTER SHEATH
    Black Low smoke and zero halogen flame retardant polyolefin (ST8)
CLASSIFICATION
    Maximum conductor temperature 90°C
    Circuit voltage not exceeding 1,200 Volts
RATED VOLTAGE
    600 Volts between Line to Earth
    1,000 Volts between Line to Line
TESTING VOLTAGE
    3,500 V
REFERENCE STANDARD
    Construction : IEC 60502-1, BS 6724
    Flame retardant : BS EN 60332-1-2
                           BS EN IEC 60332-3-22 Category A 
                           BS EN IEC 60332-3-23 Category B
                           BS EN IEC 60332-3-24 Category C 
    Acid gas emission : BS EN 60754-1, BS EN 60754-2 
    Smoke emission : BS EN 61034-2 
    Non-toxic gases : Defence standard 02-713
APPLICATION
    For Fixed installation in electrical cabinet, conduit and wireway which provide flame retardant, low smoked and non toxic emission under fire
FDLH-0.6/1KV-CCE

0.6/1kV 90°C CROSS-LINKED POLYETHYLENE INSULATED POLYOLEFIN SHEATHED FLAME RETARDANT WITH LOW SMOKE AND ZERO HALOGEN CONTROL CABLE

CONDUCTOR
    Stranded annealed copper
>
>
>
INSULATION
    Cross-Linked polyethylene(XLPE)
>
CORE IDENTIFICATION
    2 Cores : Blue and Brown
    3 Cores : Brown, Black and Grey
    4 Cores : Blue, Brown, Black and Grey
    More than 4 Cores : Black with marking numbers, colored white, printed continuously throungout the whole length of insulated wires for the propose of core indentification.
>
>
>
>
>
>
>
>
>
OUTER SHEATH
    Black Low smoke and zero halogen flame retardant polyolefin (ST8)
CLASSIFICATION
    Maximum conductor temperature 90°C
    Circuit voltage not exceeding 1,200 Volts
RATED VOLTAGE
    600 Volts between Line to Earth
    1,000 Volts between Line to Line
TESTING VOLTAGE
    3,500 V
REFERENCE STANDARD
    Construction : IEC 60502-1
    Flame retardant : BS EN 60332-1-2 
                           BS EN IEC 60332-3-22 Category A 
                           BS EN IEC 60332-3-23 Category B
                           BS EN IEC 60332-3-24 Category C 
    Acid gas emission : BS EN 60754-1, BS EN 60754-2 
    Smoke emission : BS EN 61034-2 
    Non-toxic gases : Defence standard 02-713
APPLICATION
    For Fixed installation in electrical cabinet, conduit and wireway which provide flame retardant, low smoked and non toxic emission under fire
FDLH-0.6/1KV-CCE-S

0.6/1kV 90°C CROSS-LINKED POLYETHYLENE INSULATED POLYOLEFIN SHEATHED FLAME RETARDANT WITH LOW SMOKE AND ZERO HALOGEN SHIELED CONTROL CABLE

CONDUCTOR
    Stranded annealed copper
>
>
>
INSULATION
    Cross-Linked polyethylene(XLPE)
>
CORE IDENTIFICATION
    2 Cores : Blue and Brown
    3 Cores : Brown, Black and Grey
    4 Cores : Blue, Brown, Black and Grey
    More than 4 Cores : Black with marking numbers, colored white, printed continuously throungout the whole length of insulated wires for the propose of core indentification.
>
>
INNER SHEATH
    Black Low smoke and zero halogen flame retardant polyolefin (ST8)
SHIELD
    Copper tape
>
>
>
>
>
OUTER SHEATH
    Black Low smoke and zero halogen flame retardant polyolefin (ST8)
CLASSIFICATION
    Maximum conductor temperature 90°C
    Circuit voltage not exceeding 1,200 Volts
RATED VOLTAGE
    600 Volts between Line to Earth
    1,000 Volts between Line to Line
TESTING VOLTAGE
    3,500 V
REFERENCE STANDARD
    Construction : IEC 60502-1, BS 6724
    Flame retardant : BS EN 60332-1-2 
                           BS EN IEC 60332-3-22 Category A 
                           BS EN IEC 60332-3-23 Category B
                           BS EN IEC 60332-3-24 Category C 
    Acid gas emission : BS EN 60754-1, BS EN 60754-2 
    Smoke emission : BS EN 61034-2 
    Non-toxic gases : Defence standard 02-713
APPLICATION
    For Fixed installation in electrical cabinet, conduit and wireway which provide flame retardant, low smoked and non toxic emission under fire
FS/LH-0.6/1KV-XLPE (C)

600/1000V 90°C MICA TAPE CROSS-LINKED POLYETHYLENE INSULATED FLAME RETARDANT WITH LOW SMOKE AND ZERO HALOGEN POWER CABLE

CONDUCTOR
    Non-Compacted and compacted round annealed copper 
>
>
FIRE BARRIER TAPE
    Mica tape
INSULATION
    Flame retardant Low smoke and halogen free Cross-linked polyethylene (LSHF-XLPE:EI5)
>
CORE IDENTIFICATION
    Single-core : Orange
>
>
>
>
>
>
>
>
>
>
CLASSIFICATION
    Maximum conductor temperature 90°C
    Circuit voltage not exceeding 1,200 Volts
RATED VOLTAGE
    600 Volts between Line to Earth
    1,000 Volts between Line to Line
TESTING VOLTAGE
    3,500 V
REFERENCE STANDARD
    Construction : BS EN 50525-3-41
    Circuit integrity : BS 6387 Category C, W, Z 
    Flame retardant : BS EN 60332-1-2 
                           BS EN IEC 60332-3-22 Category A 
                           BS EN IEC 60332-3-23 Category B
                           BS EN IEC 60332-3-24 Category C 
    Acid gas emission : BS EN 60754-1, BS EN 60754-2 
    Smoke emission : BS EN 61034-2 
    Non-toxic gases : Defence standard 02-713
APPLICATION
    For Fixed installation in electrical cabinet, conduit, trench and tray which provide flame retardant, low smoked and corrosive gases properties and main circuit integrity under fire.
FS-FDLH-0.6/1KV-CE

0.6/1kV 90°C MICA TAPE CROSS-LINKED POLYETHYLENE INSULATED POLYOLEFIN SHEATHED FIRE RESISTANCE FLAME RETARDANT WITH LOW SMOKE AND ZERO HALOGEN POWER CABLE

CONDUCTOR
    Non-Compacted and compacted round annealed copper 
>
>
FIRE BARRIER TAPE
    Mica tape
INSULATION
    Cross-Linked polyethylene(XLPE)
>
CORE IDENTIFICATION
    Single-core : Natural (Translucent)
    2 Core : Blue and Brown
    3 Core : Brown, Black and Grey
    4 Core : Blue, Brown, Black and Grey
>
>
>
>
>
>
>
>
>
OUTER SHEATH
    Orange Low smoke and zero halogen flame retardant polyolefin (ST8)
CLASSIFICATION
    Maximum conductor temperature 90°C
    Circuit voltage not exceeding 1,200 Volts
RATED VOLTAGE
    600 Volts between Line to Earth
    1,000 Volts between Line to Line
TESTING VOLTAGE
    3,500 V
REFERENCE STANDARD
    Construction : IEC 60502-1
    Circuit integrity : BS 6387 Category C, W, Z 
    Flame retardant : BS EN 60332-1-2 
                           BS EN IEC 60332-3-22 Category A 
                           BS EN IEC 60332-3-23 Category B
                           BS EN IEC 60332-3-24 Category C 
    Acid gas emission : BS EN 60754-1, BS EN 60754-2 
    Smoke emission : BS EN 61034-2 
    Non-toxic gases : Defence standard 02-713
APPLICATION
    For Fixed installation in electrical cabinet, conduit, trench and tray which provide flame retardant, low smoked and corrosive gases properties and main circuit integrity under fire.
FS/FDLH-0.6/1KV-CE-SWA

0.6/1kV 90°C MICA TAPE CROSS-LINKED POLYETHYLENE INSULATED POLYOLEFIN SHEATHED, WITH GALVANIZED STEEL WIRE ARMORED FLAME RETARDANT, LOW SMOKE AND ZERO HALOGEN POWER CABLE

CONDUCTOR
    Non-Compacted and compacted round annealed copper 
>
>
FIRE BARRIER TAPE
    Mica tape
INSULATION
    Cross-Linked polyethylene(XLPE)
>
CORE IDENTIFICATION
    2 Core : Blue and Brown
    3 Core : Brown, Black and Grey
    4 Core : Blue, Brown, Black and Grey
>
>
INNER SHEATH
    Black Low smoke and zero halogen flame retardant polyolefin (ST8)
>
>
>
ARMOUR
    Galvanized Steel Wires
>
>
OUTER SHEATH
    Orange Low smoke and zero halogen flame retardant polyolefin (ST8)
CLASSIFICATION
    Maximum conductor temperature 90°C
    Circuit voltage not exceeding 1,200 Volts
RATED VOLTAGE
    600 Volts between Line to Earth
    1,000 Volts between Line to Line
TESTING VOLTAGE

    3,500 V

REFERENCE STANDARD
    Construction : IEC 60502-1, BS 7846
    Circuit integrity : BS 6387 Category C, W, Z 
    Flame retardant : BS EN 60332-1-2 
                           BS EN IEC 60332-3-22 Category A 
                           BS EN IEC 60332-3-23 Category B
                           BS EN IEC 60332-3-24 Category C 
    Acid gas emission : BS EN 60754-1, BS EN 60754-2 
    Smoke emission : BS EN 61034-2 
APPLICATION
    For Fixed installation in electrical cabinet, conduit, trench and tray which provide flame retardant, low smoked and corrosive gases properties and main circuit integrity under fire.
FS/FDLH-0.6/1KV-CE-AWA

0.6/1kV 90°C MICA TAPE CROSS-LINKED POLYETHYLENE INSULATED POLYOLEFIN SHEATHED, WITH ALUMINIUM WIRE ARMORED FLAME RETARDANT, LOW SMOKE AND ZERO HALOGEN POWER CABLE

CONDUCTOR
    Non-Compacted and compacted round annealed copper 
>
>
FIRE BARRIER TAPE
    Mica tape
INSULATION
    Cross-Linked polyethylene(XLPE)
>
CORE IDENTIFICATION
    Single-core : Natural (Translucent)
>
>
INNER SHEATH
    Black Low smoke and zero halogen flame retardant polyolefin (ST8)
>
>
>
ARMOUR
    Aluminium wires
>
>
OUTER SHEATH
    Orange Low smoke and zero halogen flame retardant polyolefin (ST8)
CLASSIFICATION
    Maximum conductor temperature 90°C
    Circuit voltage not exceeding 1,200 Volts
RATED VOLTAGE
    600 Volts between Line to Earth
    1,000 Volts between Line to Line
TESTING VOLTAGE
    3,500 V
REFERENCE STANDARD
    Construction : IEC 60502-1
    Circuit integrity : BS 6387 Category C, W, Z 
    Flame retardant : BS EN 60332-1-2 
                           BS EN IEC 60332-3-22 Category A 
                           BS EN IEC 60332-3-23 Category B
                           BS EN IEC 60332-3-24 Category C 
    Acid gas emission : BS EN 60754-1, BS EN 60754-2 
    Smoke emission : BS EN 61034-2 
APPLICATION
    For Fixed installation in electrical cabinet, conduit, trench and tray which provide flame retardant, low smoked and corrosive gases properties and main circuit integrity under fire.
FS/FDLH-0.6/1KV-CCE

0.6/1kV 90°C MICA TAPE CROSS-LINKED POLYETHYLENE INSULATED POLYOLEFIN SHEATHED FIRE RESISTANT FLAME RETARDANT WITH LOW SMOKE AND ZERO HALOGEN CONTROL CABLE

CONDUCTOR
    Stranded annealed copper
>
>
FIRE BARRIER TAPE
    Mica tape
INSULATION
    Cross-Linked polyethylene(XLPE)
>
CORE IDENTIFICATION
    2 Cores : Blue and Brown
    3 Cores : Brown, Black and Grey
    4 Cores : Blue, Brown, Black and Grey
    More than 4 Cores : Black with marking numbers, colored white, printed continuously throungout the whole length of insulated wires for the propose of core indentification.
>
>
>
>
>
>
>
>
>
OUTER SHEATH
    Orange Low smoke and zero halogen flame retardant polyolefin (ST8)
CLASSIFICATION
    Maximum conductor temperature 90°C
    Circuit voltage not exceeding 1,200 Volts
RATED VOLTAGE
    600 Volts between Line to Earth
    1,000 Volts between Line to Line
TESTING VOLTAGE
    3,500 V
REFERENCE STANDARD
    Construction : IEC 60502-1
    Circuit integrity : BS 6387 Category C, W, Z 
    Flame retardant : BS EN 60332-1-2 
                           BS EN IEC 60332-3-22 Category A 
                           BS EN IEC 60332-3-23 Category B
                           BS EN IEC 60332-3-24 Category C 
    Acid gas emission : BS EN 60754-1, BS EN 60754-2 
    Smoke emission : BS EN 61034-2 
APPLICATION
    For Fixed installation in electrical cabinet, conduit, trench and tray which provide flame retardant, low smoked and corrosive gases properties and main circuit integrity under fire.
FS/FDLH-0.6/1KV-CCE-S

0.6/1kV 90°C MICA TAPE CROSS-LINKED POLYETHYLENE INSULATED POLYOLEFIN SHEATHED FIRE RESISTANT FLAME RETARDANT WITH LOW SMOKE AND ZERO HALOGEN SHIELED CONTROL CABLE

CONDUCTOR
    Stranded annealed copper
>
>
FIRE BARRIER TAPE
    Mica tape
INSULATION
    Cross-Linked polyethylene(XLPE)
>
CORE IDENTIFICATION
    2 Cores : Blue and Brown
    3 Cores : Brown, Black and Grey
    4 Cores : Blue, Brown, Black and Grey
    More than 4 Cores : Black with marking numbers, colored white, printed continuously throungout the whole length of insulated wires for the propose of core indentification.
>
>
INNER SHEATH
    Black Low smoke and zero halogen flame retardant polyolefin (ST8)
SHIELD
    Copper tape
>
>
>
>
>
OUTER SHEATH
    Orange Low smoke and zero halogen flame retardant polyolefin (ST8)
CLASSIFICATION
    Maximum conductor temperature 90°C
    Circuit voltage not exceeding 1,200 Volts
RATED VOLTAGE
    600 Volts between Line to Earth
    1,000 Volts between Line to Line
TESTING VOLTAGE
    3,500 V
REFERENCE STANDARD
    Construction : IEC 60502-1
    Circuit integrity : BS 6387 Category C, W, Z 
    Flame retardant : BS EN 60332-1-2 
                           BS EN IEC 60332-3-22 Category A 
                           BS EN IEC 60332-3-23 Category B
                           BS EN IEC 60332-3-24 Category C 
    Acid gas emission : BS EN 60754-1, BS EN 60754-2 
    Smoke emission : BS EN 61034-2 
APPLICATION
    For Fixed installation in electrical cabinet, conduit, trench and tray which provide flame retardant, low smoked and corrosive gases properties and main circuit integrity under fire.
FS/FDLH-0.6/1KV-CCE-SLA

0.6/1kV 90°C MICA TAPE CROSS-LINKED POLYETHYLENE INSULATED POLYOLEFIN SHEATHED FIRE RESISTANT FLAME RETARDANT WITH LOW SMOKE AND ZERO HALOGEN SHIELED CONTROL CABLE

CONDUCTOR
    Stranded annealed copper
>
>
FIRE BARRIER TAPE
    Mica tape
INSULATION
    Cross-Linked polyethylene(XLPE)
>
CORE IDENTIFICATION
    2 Cores : Blue and Brown
    3 Cores : Brown, Black and Grey
    4 Cores : Blue, Brown, Black and Grey
    More than 4 Cores : Black with marking numbers, colored white, printed continuously throungout the whole length of insulated wires for the propose of core indentification.
>
>
INNER SHEATH
    Black Low smoke and zero halogen flame retardant polyolefin (ST8)
SHIELD
    Laminated aluminium boned with polyester tape and drain wire
>
>
>
>
>
OUTER SHEATH
    Orange Low smoke and zero halogen flame retardant polyolefin (ST8)
CLASSIFICATION
    Maximum conductor temperature 90°C
    Circuit voltage not exceeding 1,200 Volts
RATED VOLTAGE
    600 Volts between Line to Earth
    1,000 Volts between Line to Line
TESTING VOLTAGE

    3,500 V

REFERENCE STANDARD
    Construction : IEC 60502-1
    Circuit integrity : BS 6387 Category C, W, Z 
    Flame retardant : BS EN 60332-1-2 
                           BS EN IEC 60332-3-22 Category A 
                           BS EN IEC 60332-3-23 Category B
                           BS EN IEC 60332-3-24 Category C 
    Acid gas emission : BS EN 60754-1, BS EN 60754-2 
    Smoke emission : BS EN 61034-2 
APPLICATION
    For Fixed installation in electrical cabinet, conduit, trench and tray which provide flame retardant, low smoked and corrosive gases properties and main circuit integrity under fire.