Building Wires and Cables (Copper & Aluminium)

Building Wires and Cables (Copper & Aluminium)
60227 IEC 01 THW

450/750 V 70°C SOLID AND STRANDED CONDUCTOR PVC INSULATED, SINGLE CORE

CONDUCTOR
     Solid and stranded annealed copper Size 
>
>
>
INSULATION
    Polyvinyl chloride (PVC/C)
>
CORE IDENTIFICATION
     Single – core  : Any color
>
>
>
>
>
>
>
>
>
>
CLASSIFICATION
    Maximum conductor temperature 70°C
    Circuit voltage not exceeding 450/750 Volts
RATED VOLTAGE
    450 Volts between Line to Earth
    750 Volts between Line to Line
TESTING VOLTAGE
    2,500 Volts
REFERENCE STANDARD
    TIS 11 Part 3-2553, Table 1
APPLICATION
      Building wiring for installation on insulator or in raceway dry location
60227 IEC 02 THW (f)

450/750 V 70°C FLEXIBLE CONDUCTOR PVC INSULATED , SINGLE CORE

CONDUCTOR
    Flexible annealed copper wire
>
>
>
INSULATION
    Polyvinyl chloride (PVC/C)
>
CORE IDENTIFICATION
    Single – core  : Any color
>
>
>
>
>
>
>
>
>
>
CLASSIFICATION
    Maximum conductor temperature 70°C
    Circuit voltage not exceeding 450/750 Volts
RATED VOLTAGE
    450 Volts between Line to Earth
    750 Volts between Line to Line
TESTING VOLTAGE
    2,500 Volts
REFERENCE STANDARD
    TIS 11 Part 3-2553, Table 3
APPLICATION
      Building wiring for installation on insulator or in raceway dry location
60227 IEC 05 IV

300/500 V 70°C SOLID CONDUCTOR PVC INSULATED, SINGLE CORE

CONDUCTOR
    Solid annealed copper wire
>
>
>
INSULATION
    Polyvinyl chloride (PVC/C)
>
CORE IDENTIFICATION
     Single – core  : Any color
>
>
>
>
>
>
>
>
>
>
CLASSIFICATION
      Maximum conductor temperature 70°C
      Circuit voltage not exceeding 300/500 Volts
RATED VOLTAGE
      300 Volts between Line to Earth
      500 Volts between Line to Line
TESTING VOLTAGE
    2,000 Volts
REFERENCE STANDARD
    TIS 11 Part 3-2553, Table 5
APPLICATION
    Building wiring for installation on insulator or in raceway dry location
60227 IEC 06 IV (f)

300/500 V 70°C FLEXIBLE CONDUCTOR PVC INSULATED, SINGLE CORE

CONDUCTOR
    Flexible annealed copper wire
>
>
>
INSULATION
    Polyvinyl chloride (PVC/C)
>
CORE IDENTIFICATION
    Single – core  : Any color
>
>
>
>
>
>
>
>
>
>
CLASSIFICATION
    Maximum conductor temperature 70°C
    Circuit voltage not exceeding 300/500 Volts
RATED VOLTAGE
    300 Volts between Line to Earth
    500 Volts between Line to Line
TESTING VOLTAGE
    2,000 Volts
REFERENCE STANDARD
    TIS 11 Part 3-2553, Table 7
APPLICATION
    Building wiring for installation on insulator or in raceway dry location
60227 IEC 07 HIV

300/500 V 90°C SOLID CONDUCTOR PVC INSULATED, SINGLE CORE

CONDUCTOR
    Solid annealed copper
>
>
>
INSULATION
    Polyvinyl chloride (PVC/E)
>
CORE IDENTIFICATION
    Single – core  : Any color
>
>
>
>
>
>
>
>
>
>
CLASSIFICATION
      Maximum conductor temperature 90°C
      Circuit voltage not exceeding 300/500 Volts
RATED VOLTAGE
      300 Volts between Line to Earth
      500 Volts between Line to Line
TESTING VOLTAGE
    2,000 Volts
REFERENCE STANDARD
    TIS 11 Part 3-2553, Table 9
APPLICATION
    Building wiring for installation on insulator or in raceway dry location
60227 IEC 08 HIV (f)

300/500 V 90°C FLEXIBLE CONDUCTOR PVC INSULATED, SINGLE CORE

CONDUCTOR
    Flexible annealed copper wire
>
>
>
INSULATION
    Polyvinyl chloride (PVC/E)
>
CORE IDENTIFICATION
    Single – core  : Any color
>
>
>
>
>
>
>
>
>
>
CLASSIFICATION
    Maximum conductor temperature 90°C
    Circuit voltage not exceeding 300/500 Volts
RATED VOLTAGE
      300 Volts between Line to Earth
      500 Volts between Line to Line
TESTING VOLTAGE
    2,000 Volts
REFERENCE STANDARD
    TIS 11 Part 3-2553, Table 11
APPLICATION
      Building wiring for installation on insulator or in raceway dry location
60227 IEC 10

300/500 V 70°C SOLID AND STRANDED CONDUCTOR PVC AND DOUBLE INSULATED

CONDUCTOR
    Solid and stranded annealed copper
>
>
>
INSULATION
    Polyvinyl chloride (PVC/C)
>
CORE IDENTIFICATION
    2 Cores : Blue and Brown
    3 Cores : Brown, Black and Grey
                or Blue, Brown and Green/Yellow
    4 Cores : Blue, Brown, Black and Grey
                or Brown, Black, Grey and Green/Yellow
    5 Cores : Blue, Brown, Black, Grey and Black
                or Blue, Brown, Black, Grey and Green/Yellow
>
>
>
>
>
>
>
>
>
OUTER SHEATH
    Black polyvinyl chloride (PVC/ST4)
CLASSIFICATION
    Maximum conductor temperature 70°C
    Circuit voltage not exceeding 300/500 Volts
RATED VOLTAGE
    300 Volts between Line to Earth
    500 Volts between Line to Line
TESTING VOLTAGE
    2,000 Volts
REFERENCE STANDARD
    TIS 11 Part 4-2553, Table 1
APPLICATION
    For installation exposed or in raceway, wet or dry location
60227 IEC 52 VKF

300/300 V 70°C FLEXIBLE CONDUCTOR PVC INSULATED AND SHEATHED, FLAT TYPE

CONDUCTOR
    Flexible annealed copper
>
>
>
INSULATION
    Polyvinyl chloride (PVC/D)
>
CORE IDENTIFICATION
     2 Cores : Blue and Brown
>
>
>
>
>
>
>
>
>
OUTER SHEATH
    Black Polyvinyl chloride (PVC/ST5)
CLASSIFICATION
    Maximum conductor temperature 70°C
    Circuit voltage not exceeding 300/300 Volts
RATED VOLTAGE
      300 Volts between Line to Earth
      300 Volts between Line to Line
TESTING VOLTAGE
    2,000 Volts
REFERENCE STANDARD
    TIS 11 Part 5-2553, Table 7
APPLICATION
      For household appliances, electrical equipment and electrical illumination
60227 IEC 52

300/300 V 70°C FLEXIBLE CONDUCTOR PVC INSULATED AND SHEATHED, ROUND TYPE

CONDUCTOR
    Flexible annealed copper wires
>
>
>
INSULATION
    Polyvinyl chloride (PVC/D)
>
CORE IDENTIFICATION
    2 Cores : Blue and Brown
    3 Cores : Brown, black and grey 
                or Blue, Brown and Green/Yellow
>
>
>
>
>
>
>
>
>
OUTER SHEATH
    Black Polyvinyl chloride (PVC/ST5)
CLASSIFICATION
    Maximum conductor temperature 70°C
    Circuit voltage not exceeding 300/300 Volts
RATED VOLTAGE
      300 Volts between Line to Earth
      300 Volts between Line to Line
TESTING VOLTAGE
    2,000 Volts
REFERENCE STANDARD
    TIS 11 Part 5-2553, Table 7
APPLICATION

    For household appliances, electrical equipment and electrical illumination

60227 IEC 53 VKF

300/500 V 70°C FLEXIBLE CONDUCTOR PVC INSULATED AND SHEATHED, FLAT TYPE

CONDUCTOR
    Flexible annealed copper
>
>
>
INSULATION
    Polyvinyl chloride (PVC/D)
>
CORE IDENTIFICATION
     2 Cores : Blue and Brown
>
>
>
>
>
>
>
>
>
OUTER SHEATH
    Black Polyvinyl chloride (PVC/ST5)
CLASSIFICATION
      Maximum conductor temperature 70°C
      Circuit voltage not exceeding 300/500 Volts
RATED VOLTAGE
      300 Volts between Line to Earth
      500 Volts between Line to Line
TESTING VOLTAGE
    2,000 Volts
REFERENCE STANDARD
    TIS 11 Part 5-2553, Table 9
APPLICATION
    For household appliances, electrical equipment and electrical illumination
60227 IEC 53

300/500 V 70°C FLEXIBLE CONDUCTOR PVC INSULATED AND SHEATHED, ROUND TYPE

CONDUCTOR
    Flexible annealed copper
>
>
>
INSULATION
    Polyvinyl chloride (PVC/D)
>
CORE IDENTIFICATION
    2 Cores : Blue and Brown
    3 Cores : Brown, black and grey
                or Blue, Brown and Green/Yellow
    4 Cores : Brown, Black, Grey and  Blue
                or Brown, Black, Grey and Green/Yellow
    5 Cores : Blue, Brown, Black, Grey and Black
                or Blue, Brown, Black, Grey and Green/Yellow
>
>
>
>
>
>
>
>
>
OUTER SHEATH
    Black polyvinyl chloride (PVC/ST5)
CLASSIFICATION
    Maximum conductor temperature 70°C
    Circuit voltage not exceeding 300/500 Volts
RATED VOLTAGE
    300 Volts between Line to Earth
      500 Volts between Line to Line
TESTING VOLTAGE
    2,000 Volts
REFERENCE STANDARD
    TIS 11 Part 5-2553, Table 9
APPLICATION
    For household appliances, electrical equipment and electrical illumination
60227 IEC 56 HVKF

300/300 V 90°C FLEXIBLE CONDUCTOR PVC INSULATED AND SHEATHED, FLAT TYPE

CONDUCTOR
    Flexible annealed copper
>
>
>
INSULATION
    Polyvinyl chloride (PVC/E)
>
CORE IDENTIFICATION
    2 Cores : Blue and Brown
>
>
>
>
>
>
>
>
>
OUTER SHEATH
    Black polyvinyl chloride (PVC/ST10)
CLASSIFICATION
      Maximum conductor temperature 90°C
      Circuit voltage not exceeding 300/300 Volts
RATED VOLTAGE
    300 Volts between Line to Earth
    300 Volts between Line to Line
TESTING VOLTAGE
    2,000 Volts
REFERENCE STANDARD
    TIS 11 Part 5-2553, Table 11
APPLICATION
    For household appliances, electrical equipment and electrical illumination
60227 IEC 56

300/300 V 90°C FLEXIBLE CONDUCTOR PVC INSULATED AND SHEATHED, ROUND TYPE

CONDUCTOR
    Flexible annealed copper
>
>
>
INSULATION
    Polyvinyl chloride (PVC/E)
>
CORE IDENTIFICATION
    2 Cores : Blue and Brown
    3 Cores : Brown, black and grey
                or Blue, Brown and Green/Yellow
>
>
>
>
>
>
>
>
>
OUTER SHEATH
    Black polyvinyl chloride (PVC/ST10)
CLASSIFICATION
    Maximum conductor temperature 90°C
    Circuit voltage not exceeding 300/300 Volts
RATED VOLTAGE
      300 Volts between Line to Earth
      300 Volts between Line to Line
TESTING VOLTAGE
    2,000 Volts
REFERENCE STANDARD
    TIS 11 Part 5-2553, Table 11
APPLICATION
    For household appliances, electrical equipment and electrical illumination
60227 IEC 57 HVKF

300/500 V 90°C FLEXIBLE CONDUCTOR PVC INSULATED AND SHEATHED, FLAT TYPE

CONDUCTOR
    Flexible annealed copper
>
>
>
INSULATION
    Polyvinyl chloride (PVC/E)
>
CORE IDENTIFICATION
     2 Cores : Blue and Brown
>
>
>
>
>
>
>
>
>
OUTER SHEATH
    Black polyvinyl chloride (PVC/ST10)
CLASSIFICATION
    Maximum conductor temperature 90°C
    Circuit voltage not exceeding 300/500 Volts
RATED VOLTAGE
    300 Volts between Line to Earth
    500 Volts between Line to Line
TESTING VOLTAGE
    2,000 Volts
REFERENCE STANDARD
    TIS 11 Part 5-2553, Table 13
APPLICATION
    For household appliances, electrical equipment and electrical illumination
60227 IEC 57

300/500 V 90°C FLEXIBLE CONDUCTOR PVC INSULATED AND SHEATHED, ROUND TYPE

CONDUCTOR
    Flexible annealed copper 
>
>
>
INSULATION
    Polyvinyl chloride (PVC/E)
>
CORE IDENTIFICATION
    2 Cores : Blue and Brown
    3 Cores : Brown, black and grey
                or Blue, Brown and Green/Yellow
    4 Cores : Brown, Black, Grey and Blue
                or Brown, Black, Grey and Green/Yellow
    5 Cores : Blue, Brown, Black, Grey and Black 
                or Blue, Brown, Black, Grey and Green/Yellow
>
>
>
>
>
>
>
>
>
OUTER SHEATH
      Black polyvinyl chloride (PVC/ST10)
CLASSIFICATION
      Maximum conductor temperature 90°C
      Circuit voltage not exceeding 300/500 Volts
RATED VOLTAGE
    300 Volts between Line to Earth
    500 Volts between Line to Line
TESTING VOLTAGE
    2,000 Volts
REFERENCE STANDARD
    TIS 11 Part 5-2553, Table 13
APPLICATION
    For household appliances, electrical equipment and electrical illumination
VAF

300/500 V 70°C SOLID AND STRANDED CONDUCTOR PVC INSULATED AND SHEATHED, FLAT TYPE

CONDUCTOR
    Solid and stranded annealed copper
>
>
>
INSULATION
    Polyvinyl chloride (PVC/C)
>
CORE IDENTIFICATION
    2 Core : Blue and Brown
>
>
>
>
>
>
>
>
>
OUTER SHEATH
      White polyvinyl chloride (PVC/ST4)
CLASSIFICATION
      Maximum conductor temperature 70°C
      Circuit voltage not exceeding 300/500 Volts
RATED VOLTAGE
      300 Volts between Line to Earth
        500 Volts between Line to Line
TESTING VOLTAGE
    2,000 Volts
REFERENCE STANDARD
    TIS 11 Part 101-2559, Table 1
APPLICATION
    Building wiring for surface or above ceiling wiring or direct embeded in plaster
VAF-G

300/500 V 70°C SOLID AND STRANDED CONDUCTOR PVC INSULATED AND SHEATHED WITH GROUND, FLAT TYPE

CONDUCTOR
    Solid and stranded annealed copper
>
>
>
INSULATION
    Polyvinyl chloride (PVC/C)
>
CORE IDENTIFICATION
    2 Core +Ground : Blue, Brown and Green/Yellow
>
>
>
>
>
>
>
>
>
OUTER SHEATH
    White polyvinyl chloride (PVC/ST4)
CLASSIFICATION
    Maximum conductor temperature 70°C
    Circuit voltage not exceeding 300/500 Volts
RATED VOLTAGE
    300 Volts between Line to Earth
      500 Volts between Line to Line
TESTING VOLTAGE
    2,000 Volts
REFERENCE STANDARD
    TIS 11 Part 101-2559, Table 1
APPLICATION
    Building wiring for surface or above ceiling wiring or direct embeded in plaster
NYY

450/750 V 70°C SOLID AND STRANDED CONDUCTOR PVC INSULATED AND DOUBLE SHEATHED

CONDUCTOR
    Solid and stranded annealed copper
>
>
>
INSULATION

    Black polyvinyl chloride (PVC)

>
CORE IDENTIFICATION
    Single-core : Black
    2 Core : Blue and Brown
    3 Core : Brown, Black and Grey
    4 Core : Blue, Brown, Black and Grey
>
>
INNER SHEATH
    Black polyvinyl chloride (PVC)
>
>
>
>
>
>
OUTER SHEATH
    Black polyvinyl chloride (PVC/ST4)
CLASSIFICATION
    Maximum conductor temperature 70°C
    Circuit voltage not exceeding 450/750 Volts
RATED VOLTAGE
      450 Volts between Line to Earth
      750 Volts between Line to Line
TESTING VOLTAGE
    2,500 Volts
REFERENCE STANDARD
    TIS 11 Part 101-2559, Table 3
    TIS 11 Part 101-2559, Table 4
APPLICATION
    For installation exposed or in raceway, wet or dry location, or direct burial in ground
NYY - G

450/750 V 70°C STRANDED CONDUCTOR PVC INSULATED AND DOUBLE SHEATHED WITH GROUND

CONDUCTOR
    Solid and stranded annealed copper
>
>
>
INSULATION
    Polyvinyl chloride (PVC/C)
>
CORE IDENTIFICATION
    2 Core + Ground : Blue and Brown + Green/Yellow
    3 Core + Ground: Brown, Black and Grey + Green/Yellow
    4 Core + Ground : Blue, Brown, Black and Grey + Green/Yellow
>
>
>
>
>
>
>
>
>
OUTER SHEATH
    Black polyvinyl chloride (PVC/ST4)
CLASSIFICATION
    Maximum conductor temperature 70°C
    Circuit voltage not exceeding 450/750 Volts
RATED VOLTAGE
    450 Volts between Line to Earth
    750 Volts between Line to Line
TESTING VOLTAGE
    2,500 Volts
REFERENCE STANDARD
    TIS 11 Part 101-2559, Table 5
APPLICATION
    For installation exposed or in raceway, wet or dry location, or direct burial in ground
VCT

450/750 V 70°C FLEXIBLE CONDUCTOR PVC INSULATED AND SHEATHED, ROUND TYPE

CONDUCTOR
     Flexible annealed copper
>
>
>
INSULATION
    Polyvinyl chloride (PVC/D)
>
CORE IDENTIFICATION
    Single-core : Black
    2 Core : Blue and Brown
    3 Core : Brown, Black and Grey
    4 Core : Blue, Brown, Black and Grey

>
>
>
>
>
>
>
>
>
OUTER SHEATH
    Black polyvinyl chloride (PVC/ST5)
CLASSIFICATION
      Maximum conductor temperature 70°C
      Circuit voltage not exceeding 450/750 Volts
RATED VOLTAGE
    450 Volts between Line to Earth 
    750 Volts between Line to Line
TESTING VOLTAGE
    2,500 Volts
REFERENCE STANDARD
    TIS 11 Part 101-2559, Table 7
APPLICATION
    For mobile-electrical equipment used in mines, factories, farm or household appliances. This cable is suitable for use in place where cable come in contact with oils
VCT -G

450/750 V 70°C FLEXIBLE CONDUCTOR PVC INSULATED AND SHEATHED WITH GOUND, ROUND TYPE

CONDUCTOR
    Flexible annealed copper wire

>
>
>
INSULATION
    Polyvinyl chloride (PVC/D)
>
CORE IDENTIFICATION
    2 Core + Ground : Blue and Brown + Green/Yellow
    3 Core + Ground: Brown, Black and Grey + Green/Yellow
    4 Core + Ground : Blue, Brown, Black and Grey + Green/Yellow
>
>
>
>
>
>
>
>
>
OUTER SHEATH
    Black polyvinyl chloride (PVC/ST5)
CLASSIFICATION
    Maximum conductor temperature 70°C
    Circuit voltage not exceeding 450/750 Volts
RATED VOLTAGE
      450 Volts between Line to Earth
      750 Volts between Line to Line
TESTING VOLTAGE
    2,500 Volts
REFERENCE STANDARD
    TIS 11 Part 101-2559, Table 8
APPLICATION
    For mobile-electrical equipment used in mines, factories, farm or household appliances. This cable is suitable for use in place where cable come in contact with oils
THWA

750 V 70°C ALUMINIUM CONDUCTOR PVC INSULATED, SINGLE CORE

CONDUCTOR
    Solid and stranded hard drawn aluminium wires
>
>
>
INSULATION
    Black polyvinyl chloride (PVC)
>
>
>
>
>
>
>
>
>
>
>
>
CLASSIFICATION
    Maximum conductor temperature 70°C
    Circuit voltage not exceeding 750 Volts
>
TESTING VOLTAGE
    2,500 Volts
REFERENCE STANDARD
    TIS 293-2541, Table 1
APPLICATION
    For low voltage overhead distribution line
THWA-C

750 V 70°C COMPACTED ALUMINIUM CONDUCTOR PVC INSULATED, SINGLE CORE

CONDUCTOR
    Compacted stranded hard drawn aluminium wires
>
>
>
INSULATION
    Black polyvinyl chloride (PVC)
>
>
>
>
>
>
>
>
>
>
>
>
CLASSIFICATION
    Maximum conductor temperature 70°C
    Circuit voltage not exceeding 750 Volts
>
TESTING VOLTAGE
    2,500 Volts
REFERENCE STANDARD
    TIS 293-2541, Table 1
APPLICATION
    For low voltage overhead distribution line