• 69 KV-CE

    69 kV 90°C CROSS-LINKED POLYETHYLENE INSULATED WITH COPPER WIRE SCREEN AND POLYETHYLENE JACKETED POWER CABLE


    Conductor   : Compact concentric stranded uncoated
    annealed copper conductor,
    Single-core : Size 400 mm²  up to 800 mm²
     
    Insulation : Cross-Linked polyethylene (XLPE)
     
    Core identification Single-core : Natural (Translucent)
     
    Outer sheath : Polyethylene (PE)
     
    Classification : Maximum conductor temperature 90°C
     
    Testing voltage : 90,000 Volts
     
    Reference standard : TIS 2202, TIS 2427
      (IEC 60840, IEC 60228)
  • 115 KV-CE

    115 kV 90°C CROSS-LINKED POLYETHYLENE INSULATED WITH COPPER WIRE SCREEN AND POLYETHYLENE JACKETED POWER CABLE


    Conductor   : Compact concentric stranded uncoated
    annealed copper conductor,
    Single-core : Size 400 mm²  up to 800 mm²
     
    Insulation : Cross-Linked polyethylene (XLPE)
     
    Core identification Single-core : Natural (Translucent)
     
    Outer sheath : Polyethylene (PE)
     
    Classification : Maximum conductor temperature 90°C
     
    Testing voltage : 160,000 Volts
     
    Reference standard : TIS 2202, TIS 2427
      (IEC 60840, IEC 60228)
  • 24 KV-OC

    24 KV CROSS-LINKED POLYETHYLENE PARTIAL INSULATED ALL ALUMINIUM CABLE


    Conductor   : Compacted round stranded hard drawn
      aluminium wires
    Single-core : Size 35 mm²  up to 185 mm²
     
    Insulation : Cross-linked polyethylene (XLPE)
     
    Core indentification Color : Black
     
    Classification : Maximum conductor temperature 90°C
    : Circuit voltage not exceeding 24,000 Volts
     
    Testing voltage : 11,000 Volts
     
    Reference standard : ICEA S-66-524, ICEA S-93-639
  • 33 KV-OC

    33 kV CROSS-LINKED POLYETHYLENE PARTIAL INSULATED ALL ALUMINIUM CABLE


    Conductor   : Compacted round stranded hard drawn
      aluminium wires
    Single-core : Size 35 mm²  up to 185 mm²
     
    Insulation : Cross-linked polyethylene (XLPE)
     
    Core indentification Color : Black
     
    Classification : Maximum conductor temperature 90°C
    : Circuit voltage not exceeding 33,000 Volts
     
    Testing voltage : 17,000 Volts
     
    Reference standard : ICEA S-66-524, ICEA S-93-639
  • 15 KV-CC

    15 kV ALL ALUMINIUM CONDUCTOR SPACED AERIAL CABLE


    Conductor   : Compacted round stranded hard drawn
      aluminium wires
    Single-core : Size 35 mm²  up to 240 mm²
     
    Insulation : Cross-linked polyethylene (XLPE)
      Color : Natural
     
    Outer sheath : Cross-linked polyethylene (XLPE)
      Color : Black
     
    Classification : Maximum conductor temperature 90°C
    : Circuit voltage not exceeding 15,000 Volts
     
    Testing voltage : 27,000 Volts
     
    Reference standard : ICEA S-66-524, ICEA S-93-639
  • 25 KV-CC

    25 kV ALL ALUMINIUM CONDUCTOR SPACED AERIAL CABLE


    Conductor   : Compacted round stranded hard drawn
      aluminium wires
    Single-core : Size 35 mm²  up to 240 mm²
     
    Insulation : Cross-linked polyethylene (XLPE)
      Color : Natural
     
    Outer sheath : Cross-linked polyethylene (XLPE)
      Color : Black
     
    Classification : Maximum conductor temperature 90°C
    : Circuit voltage not exceeding 25,000 Volts
     
    Testing voltage : 38,000 Volts
     