• 500V-NYY-SWA

    300/500 V 70°C PVC INSULATED AND DOUBLE SHEATHED, WITH GALVANIZED STEEL WIRES ARMORED POWER CABLE


    Conductor   : Solid and stranded annealed copper,
      Size 1.5 mm²  up to 35 mm²
    Insulation : Polyvinyl chloride (PVC/C)
    Core identification 2 Core : Blue and Brown
    3 Core : Brown, Black and Grey
    4 Core : Blue, Brown, Black and Grey
    Other colors are available on customer request
    Armor : Galvanized Steel Wires
    Inner sheath : Black polyvinyl chloride (PVC)
    Outer sheath : Black polyvinyl chloride (PVC/ST4)
    Classification : Maximum conductor temperature 70°C
    : Circuit voltage not exceeding 300/500 Volts
      300 Volts between Line-to-Earth
      500 Volts between Line-to-Line
    Testing voltage : 2,000 Volts
    Reference standard : TIS 11 Part 4-2553
  • NYY-SWA

    450/750 V 70°C PVC INSULATED AND DOUBLE SHEATHED, WITH GALVANIZED STEEL WIRES ARMORED POWER CABLE


    Conductor   : Solid and stranded annealed copper,
      Size 50 mm²  up to 300 mm²
     
    Insulation : Polyvinyl chloride (PVC/C)
     
    Core identification 2 Core : Blue and Brown
    3 Core : Brown, Black and Grey
    4 Core : Blue, Brown, Black and Grey
    Other colors are available on customer request
     
    Armor : Galvanized Steel Wires
     
    Inner sheath : Black polyvinyl chloride (PVC)
     
    Outer sheath : Black polyvinyl chloride (PVC/ST4)
     
    Classification : Maximum conductor temperature 70°C
    : Circuit voltage not exceeding 450/750 Volts
      450 Volts between Line-to-Earth
      750 Volts between Line-to-Line
     
    Testing voltage : 2,500 Volts
     
    Reference standard : TIS 11 Part 101-2553
  • 500V-NYCY

    300/500 V 70°C PVC INSULATED AND DOUBLE SHEATHED, WITH CONCENTRIC CONDUCTORS POWER CABLE


    Conductor   : Concentric stranded annealed copper wires,
      Size 1.5 mm²  up to 35 mm²
     
    Concentric shield : Annealed copper wires with helix of copper tape
      fully covers
     
    Insulation : Polyvinyl chloride (PVC/C)
     
    Core identification 3 Core : Brown, Black and Grey
    Other colors are available on customer request
     
    Inner sheath : Black polyvinyl chloride (PVC)
     
    Outer sheath : Black polyvinyl chloride (PVC/ST4)
     
    Classification : Maximum conductor temperature 70°C
    : Circuit voltage not exceeding 300/500 Volts
      300 Volts between Line-to-Earth
      500 Volts between Line-to-Line
     
    Testing voltage : 2,000 Volts
     
    Reference standard : TIS 11 Part 4-2553
  • NYCY

    450/750 V 70°C PVC INSULATED AND DOUBLE SHEATHED, WITH CONCENTRIC CONDUCTORS POWER CABLE


    Conductor   : Concentric stranded annealed copper wires,
      Size 50 mm²  up to 300 mm²
     
    Concentric shield : Annealed copper wires with helix of copper tape
      fully covers
     
    Insulation : Polyvinyl chloride (PVC/C)
     
    Core identification 3 Core : Brown, Black and Grey
    Other colors are available on customer request
     
    Inner sheath : Polyvinyl chloride (PVC)
     
    Outer sheath : Black polyvinyl chloride (PVC/ST4)
     
    Classification : Maximum conductor temperature 70°C
    : Circuit voltage not exceeding 450/750 Volts
      450 Volts between Line-to-Earth
      750 Volts between Line-to-Line
     
    Testing voltage : 2,500 Volts
     
    Reference standard : TIS 11 Part 101-2553
  • FD-0.6/1 KV-CV-SWA

    0.6/1 KV 90°C CROSS-LINKED POLYETHYLENE INSULATED PVC SHEATHED, WITH GALVANIZED STEEL WIRES ARMORED POWER CABLE


    Conductor   : Concentric stranded and compacted stranded
      annealed copper,
    Size 1.5 mm²  up to 400 mm²
    Insulation Cross-linked Polyethylene (XLPE)
    Color : Natural (Translucent)
    Core identification Compound color or color tape
    2 Core : Blue and Brown
    3 Core : Brown, Black and Grey
    4 Core : Blue, Brown, Black and Grey
    Other colors are available on customer request
    Armor : Galvanized steel wires
    Inner sheath : Black polyvinyl chloride (PVC)
    Outer sheath : Black polyvinyl chloride (PVC/ST2)
    Classification : Maximum conductor temperature 90°C
    : Circuit voltage not exceeding 1,200 Volts
      Rated voltage (U0 /U) 0.6/1 KV
      600 Volts between Line-to-Earth
      1,000 Volts between Line-to-Line
    Testing voltage : 3,500 Volts
    Reference standard : IEC 60502-1, IEC 60228, IEC 60332-1
  • FD-0.6/1KV-CV

    0.6/1(1.2)kV 90 0C XLPE Insulated PVC Jacketed Flame retardant Power cable


    Conductor   : Concentric stranded and compacted round
      annealed copper,
    Single-core : Size 1.5 mm²  up to 1,000 mm²
    Multi-core : Size 1.5 mm²  up to 400 mm²
     
    Insulation : Cross-linked Polyethylene (XLPE)
    Core identification Single-core : Natural (Translucent)
    2 Core : Blue and Brown
    3 Core : Brown, Black and Grey
    4 Core : Blue, Brown, Black and Grey
    Other colors are available on customer request
     
    Inner sheath : Black polyvinyl chloride (PVC/ST2)
    Outer sheath : Black polyvinyl chloride (PVC/ST4)
    Classification : Maximum conductor temperature 90°C
    : Circuit voltage not exceeding 1,200 Volts
      Rated voltage (U/U) 0.6/1 KV
      600 Volts between Line-to-Earth
      1,000 Volts between Line-to-Line
     
    Testing voltage : 3,500 Volts
    Reference standard : IEC 60502-1, IEC 60228, IEC 60332-1