• 60227 IEC 56 HVKF

    300/300 V 90°C FLEXIBLE CONDUCTOR PVC INSULATED AND SHEATHED, FLAT TYPE


    Conductor   : Flexible annealed copper wires
      Size 0.5 mm ² and 0.75 mm²
     
    Insulation : Polyvinyl chloride (PVC/E)
     
    Core identification  2 Cores : Blue and Brown
     
    Outer sheath : Black polyvinyl chloride (PVC/ST10)
     
    Classification : Maximum conductor temperature 90°C
    : Circuit voltage not exceeding 300/300 Volts
      300 Volts between Line-to-Earth
      300 Volts between Line-to-Line
     
    Testing voltage : 2,000 Volts
     
    Reference standard : TIS 11 Part 5-2553, Table 11
  • 60227 IEC 56

    300/300 V 90°C FLEXIBLE CONDUCTOR PVC INSULATED AND SHEATHED, ROUND TYPE


    Conductor   : Flexible annealed copper wires
      Size 0.5 mm ² and 0.75 mm²
     
    Insulation : Polyvinyl chloride (PVC/E)
     
    Core identification 2 Cores : Blue and Brown
    3 Cores : Brown, black and grey
                    or Blue, Brown and Green/Yellow
     
    Outer sheath : Black polyvinyl chloride (PVC/ST10)
     
    Classification : Maximum conductor temperature 90°C
    : Circuit voltage not exceeding 300/300 Volts
      300 Volts between Line-to-Earth
      300 Volts between Line-to-Line
     
    Testing voltage : 2,000 Volts
     
    Reference standard : TIS 11 Part 5-2553, Table 11
  • 60227 IEC 57 HVKF

    300/500 V 90°C FLEXIBLE CONDUCTOR PVC INSULATED AND SHEATHED, FLAT TYPE


    Conductor   : Flexible annealed copper wires
      Size 0.75 mm ² and 1 mm²
     
    Insulation : Polyvinyl chloride (PVC/E)
     
    Core identification  2 Cores : Blue and Brown  
     
    Outer sheath : Black polyvinyl chloride (PVC/ST10)
     
    Classification : Maximum conductor temperature 90°C
    : Circuit voltage not exceeding 300/500 Volts
      300 Volts between Line-to-Earth
      500 Volts between Line-to-Line
     
    Testing voltage : 2,000 Volts
     
    Reference standard : TIS 11 Part 5-2553, Table 13
  • 60227 IEC 57

    300/500 V 90°C FLEXIBLE CONDUCTOR PVC INSULATED AND SHEATHED, ROUND TYPE


    Conductor   : Flexible annealed copper wires
      Size 0.75 mm ² and 2.5 mm²
     
    Insulation : Polyvinyl chloride (PVC/E)
     
    Core identification 2 Cores : Blue and Brown
    3 Cores : Brown, black and grey
                    or Blue, Brown and Green/Yellow
    4 Cores : Brown, Black, Grey and Blue
                    or Brown, Black, Grey and Green/Yellow
    5 Cores : Blue, Brown, Black, Grey and Black
                    or Blue, Brown, Black, Grey and Green/Yellow
     
    Outer sheath : Black polyvinyl chloride (PVC/ST10)
     
    Classification : Maximum conductor temperature 90°C
    : Circuit voltage not exceeding 300/500 Volts
      300 Volts between Line-to-Earth
      500 Volts between Line-to-Line
     
    Testing voltage : 2,000 Volts
     
    Reference standard : TIS 11 Part 5-2553, Table 13
  • VAF

    300/500 V 70°C SOLID AND STRANDED CONDUCTOR PVC INSULATED AND SHEATHED, FLAT TYPE


    Conductor   : Solid and stranded annealed copper, Size            1 mm²
      up to 16 mm²
     
    Insulation : Polyvinyl chloride (PVC/C)
     
    Core identification 2 Core : Blue and Brown
     
    Outer sheath : White polyvinyl chloride (PVC/ST4)
     
    Classification : Maximum conductor temperature 70°C
    : Circuit voltage not exceeding 300/500 Volts
      300 Volts between Line-to-Earth
      500 Volts between Line-to-Line
     
    Testing voltage : 2,000 Volts
     
    Reference standard : TIS 11 Part 101-2553, Table 1
  • VAF-G

    300/500 V 70°C SOLID AND STRANDED CONDUCTOR PVC INSULATED AND SHEATHED WITH GROUND, FLAT TYPE


    Conductor   : Solid and stranded annealed copper, Size            1 mm²
      up to 16 mm²
     
    Ground wire : Solid and stranded annealed copper, Size 1 mm²
      up to 16 mm²
     
    Insulation : Polyvinyl chloride (PVC/C)
     
    Core identification 2 Core : Blue and Brown
    Ground-Cores : Green/Yellow
     
    Outer sheath : White polyvinyl chloride (PVC/ST4)
     
    Classification : Maximum conductor temperature 70°C
    : Circuit voltage not exceeding 300/500 Volts
      300 Volts between Line-to-Earth
      500 Volts between Line-to-Line
     
    Testing voltage : 2,000 Volts
     
    Reference standard : TIS 11 Part 101-2553, Table 1