• 60227 IEC 01 THW

    450/750 V 70°C SOLID AND STRANDED CONDUCTOR PVC INSULATED, SINGLE CORE


    Conductor   : Solid and stranded annealed copper Size                      1.5mm² up to 400 mm²
     
    Insulation : Polyvinyl chloride (PVC/C)
     
    Core identification : Single – core  : Any color
       
    Classification : Maximum conductor temperature 70°C
    : Circuit voltage not exceeding 450/750 Volts
      450 Volts between Line-to-Earth
      750 Volts between Line-to-Line

     
    Testing voltage : 2,500 Volts
     
    Reference standard : TIS 11 Part 3-2553, Table 1
     
  • 60227 IEC 02 THW (f)

    450/750 V 70°C FLEXIBLE CONDUCTOR PVC INSULATED , SINGLE CORE


    Conductor   : Flexible annealed copper wire Size 1.5 mm² up to 240   mm²
     
    Insulation : Polyvinyl chloride (PVC/C)
     
    Core identification : Single – core  : Any color
       
    Classification : Maximum conductor temperature 70°C
    : Circuit voltage not exceeding 450/750 Volts
      450 Volts between Line-to-Earth
      750 Volts between Line-to-Line
     
    Testing voltage : 2,500 Volts
     
    Reference standard : TIS 11 Part 3-2553, Table 3
  • 60227 IEC 05 IV

    300/500 V 70°C SOLID CONDUCTOR PVC INSULATED, SINGLE CORE


    Conductor   : Solid annealed copper, Size 0.5 mm² up to 1            mm²
     
    Insulation : Polyvinyl chloride (PVC/C)
     
    Core identification : Single – core  : Any color
       
    Classification : Maximum conductor temperature 70°C
    : Circuit voltage not exceeding 300/500 Volts
      300 Volts between Line-to-Earth
      500 Volts between Line-to-Line
     
    Testing voltage : 2,000 Volts
     
    Reference standard : TIS 11 Part 3-2553, Table 5
  • 60227 IEC 06 IV (f)

    300/500 V 70°C FLEXIBLE CONDUCTOR PVC INSULATED, SINGLE CORE


    Conductor   : Flexible annealed copper wire Size 0.5 mm² up to 1 mm²
     
    Insulation : Polyvinyl chloride (PVC/C)
     
    Core identification : Single – core  : Any color
       
    Classification : Maximum conductor temperature 70°C
    : Circuit voltage not exceeding 300/500 Volts
      300 Volts between Line-to-Earth
      500 Volts between Line-to-Line
     
    Testing voltage : 2,000 Volts
     
    Reference standard : TIS 11 Part 3-2553, Table 7
  • 60227 IEC 07 HIV

    300/500 V 90°C SOLID CONDUCTOR PVC INSULATED, SINGLE CORE


    Conductor   : Solid annealed copper, Size 0.5 mm² up to 2.5        mm²
     
    Insulation : Polyvinyl chloride (PVC/E)
     
    Core identification : Single – core  : Any color
       
    Classification : Maximum conductor temperature 90°C
    : Circuit voltage not exceeding 300/500 Volts
      300 Volts between Line-to-Earth
      500 Volts between Line-to-Line
     
    Testing voltage : 2,000 Volts
     
    Reference standard : TIS 11 Part 3-2553, Table 9
  • 60227 IEC 08 HIV (f)

    300/500 V 90°C FLEXIBLE CONDUCTOR PVC INSULATED, SINGLE CORE


    Conductor   : Flexible annealed copper wire Size 0.5 mm² up to 2.5 mm²
     
    Insulation : Polyvinyl chloride (PVC/E)
     
    Core identification : Single – core  : Any color
       
    Classification : Maximum conductor temperature 90°C
    : Circuit voltage not exceeding 300/500 Volts
      300 Volts between Line-to-Earth
      500 Volts between Line-to-Line
     
    Testing voltage : 2,000 Volts
     
    Reference standard : TIS 11 Part 3-2553, Table 11